Comparative study of two methodologies for structural shielding design of imaging facilities
DOI:
https://doi.org/10.29384/rbfm.2011.v5.n2.p205-208Resumo
The present study aimed at showing which implications can be found in structural radiation shielding design, depending on the calculation method adopted. Two methods were analyzed: one that considers the sum of thickness contributions, and other that considers the sum of unshielded air kerma contributions. To compare the results, a case analysis was done. A hypothetical radiographic room, which contains a table of exam and a chest bucky, was considered. The thickness contribution method presented the highest results, reaching a maximum relative difference of 85% from the results of the 147 National Council of Radiation Protection and Measurements, and 57% from the unshielded air kerma contributions method.Downloads
Downloads
Como Citar
Edição
Seção
Licença
A submissão de artigos originais para a Revista Brasileira de Física Médica implica na transferência, pelos autores, dos direitos de publicação impressa e digital. Os direitos autorais para os artigos publicados são do autor, com direitos do periódico sobre a primeira publicação. Os autores somente poderão utilizar os mesmos resultados em outras publicações indicando claramente este periódico como o meio da publicação original. Em virtude de sermos um periódico de acesso aberto, permite-se o uso gratuito dos artigos em aplicações educacionais, científicas, não comerciais, desde que citada a fonte.
A Revista Brasileira de Física Médica está sob a Licença Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0).