End-to-end Verification of Automated SRS with HyperArc on the TrueBeam Platform

Autores

  • Matheus Fernando Santos Real Hospital Português de beneficência em Pernambuco https://orcid.org/0000-0003-0477-249X
  • Lucas Delbem Albino Real Hospital Português de beneficência em Pernambuco https://orcid.org/0000-0002-2467-4574
  • Karen Pieri Bueno Real Hospital Português de beneficência em Pernambuco https://orcid.org/0000-0001-8584-6934
  • Ueslen Santos da Silva Hospital de Amor de Barretos
  • Jose Geneci da Costa Calado Real Hospital Português de beneficência em Pernambuco
  • Roberta Silva Oliveira Real Hospital Português de beneficência em Pernambuco https://orcid.org/0009-0006-9168-5237
  • Jessica Luana Oliveira Barbosa
  • Luccas Moreira Alves Real Hospital Português de beneficência em Pernambuco https://orcid.org/0009-0002-2676-6613
  • Ernesto Henrique Roesler Real Hospital Português de beneficência em Pernambuco

DOI:

https://doi.org/10.29384/rbfm.2023.v17.19849001742

Palavras-chave:

dose de radiação, exames radiológicos, planejamento radioterápico, radioterapia.

Resumo

A Radiocirurgia estereotáxica (SRS) é uma técnica de tratamento extremamente complexa, pois envolve várias etapas e consiste em administrar elevadas doses de radiação em poucas aplicações. Dentre as etapas estão procedimentos de aquisição de imagens, registro de imagens, definição do volume alvo, planejamento do tratamento e cálculo de dose, posicionamento do paciente com sistema de IGRT, bem como a entrega do tratamento no equipamento. O teste de ponta a ponta (E2E) é capaz de nos fornecer a incerteza combinada de todo o processo envolvido em procedimentos complexos, como é a SRS. Este estudo consistiu em simular todo o fluxo de tratamento de um paciente em um simulador antropomórfico, e: (i) analisar a aquisição das imagens e o registro, de maneira qualitativa e quantitativa, (ii) realizar o planejamento de tratamento nesse simulador e (iii) verificar a entrega de dose de radiação por meio da medida de dose absoluta com câmara de ionização e análise da distribuição de dose planar com filme radiocrômico. Os resultados das análises quantitativas dos registros através do TRE e DSC foram consideradas satisfatórias, segundo as tolerâncias do TG-132. Os resultados das medidas com câmara de ionização para determinação da dose absoluta pontual apresentaram variações inferiores a 3% do valor calculado pelo TPS. A análise da distribuição de dose planar com filme radiocrômico mostrou que há concordância entre o perfil de dose calculado pelo TPS e o medido, com taxa de aceitação superior a 98% no critério gama de 3%/1mm. A recomendação para a frequência do teste E2E é pelo menos anual, ou após algum reparo ou substituição de equipamento com potencial impacto na integridade dos dados e a cada atualização de software de registro de imagem ou TPS.

Downloads

Biografia do Autor

Matheus Fernando Santos, Real Hospital Português de beneficência em Pernambuco

Departamento de energia nuclear (DEN/UFPE)

Referências

Benedict S. H., et al. Stereotactic body radiation therapy: the report of AAPM Task Group 101. Med. Phys.; v. 37(8), p.4078- 4101, 2010.

Halvorsen, P. H., Cirino E., Das I. J., et al. AAPM-RSS medical physics practice guideline 9.a. for SRS-SBRT. J. Applied Clinical Med. Phys., v. 18(5), p.10 – 21, 2017.

Otto K. Volumetric modulated arc therapy: IMRT in a single gantry arc. Med. Phys., v. 35, 2008.

Sharpe, M. B., IAEA Technical Reports Series No. 430: Commissioning and Quality Assurance of Computerized Planning Systems for Radiation Treatment of Cancer. Med. Phys., v. 33(2), p.561-561, 2006.

Grishchuk, D., et al. ISRS Technical Guidelines for Stereotactic Radiosurgery: Treatment of Small Brain Metastases (≤1 cm in Diameter). Prac. Rad. Onc., e1-e12, 2022.

Lim, S. B., et al. Comparative study of SRS end-to-end QA processes of a diode array device and an anthropomorphic phantom loaded with GafChromic XD film. J. Applied Clinical Med. Phys., v. 23(9), p.10 – 21, 2022.

American Association of Physicists in Medicine (AAPM). Radiation Therapy Committee Task Group 132: Use of image registration and fusion algorithms and techniques in radiotherapy. Med. Phys., v. 44(7), 2017.

Low, C., Toye W., Phung, P., Huston, C. Patient-Specific Quality Assurance Protocol for Volumetric Modulated Arc Therapy using Dose Volume Histogram. Journal Med. Phys., v.43(25), p.112 – 118, 2018.

Shaw E, Kline R, Gillin M, et al: Radiation Therapy Oncology Group: radiosurgery quality assurance guidelines. Int. J. Radiat. Oncol. Biol. Phys., v.27, p.1231–1239, 1993.

Paddick I. A simple scoring ratio to index the conformity of radiosurgical treatment plans. J. Neurosurg. V. 93(3), p. 219-222, 2000.

Desai, D. D., Johnson, E. L., Cordrey, I., L. An analytical expression for R50% dependent on PTV surface area and volume: A cranial SRS comparison. J. Applied Clinical Med. Phys., v. 22(2), p.203 – 210, 2021.

American Association of Physicists in Medicine (AAPM). Radiation Therapy Committee Task Group 119: Commissioning Tests Instructions for Planning, Measurement, and analysis. 2009.

Low, D. A., Harms, W. B., Mutic, S., Purdy, J.A. A technique for the quantitative evaluation of dose distributions. Med. Phys., v. 25, p.656–61, 1998.

Miften, M., Olch, A., Mihailidis, D., et al. Tolerance limits and methodologies for IMRT measurement-based verification QA: recommendations of AAPM Task Group 218. Med. Phys., v.45 (4), e53- e83, 2018.

Furnari, L. e Colaboradores. Controle da qualidade em radioterapia. 2ª Ed. São Paulo, Brasil (2021).

Downloads

Publicado

2023-11-28

Como Citar

Santos, M. F., Delbem Albino, L., Pieri Bueno, K., Santos da Silva, U., Geneci da Costa Calado, J., Silva Oliveira, R., Luana Oliveira Barbosa, J., Moreira Alves, L., & Henrique Roesler, E. (2023). End-to-end Verification of Automated SRS with HyperArc on the TrueBeam Platform . Revista Brasileira De Física Médica, 17, 742. https://doi.org/10.29384/rbfm.2023.v17.19849001742

Edição

Seção

Artigo Original

Artigos mais lidos pelo mesmo(s) autor(es)